{"product_id":"mgl-capacitance-fuel-level-senders","title":"MGL Capacitance Fuel Level Senders","description":"\u003ch2 data-start=\"44\" data-end=\"99\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cul data-start=\"101\" data-end=\"438\"\u003e\n\u003cli data-start=\"101\" data-end=\"179\"\u003e\n\u003cp data-start=\"103\" data-end=\"179\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eManufacturer \/ Model: MGL Avionics (probe made by Centroid Products), sold under part numbers LEVELSND‑12 (12″) and LEVELSND‑24 (24″) \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"180\" data-end=\"258\"\u003e\n\u003cp data-start=\"182\" data-end=\"258\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-start=\"0\" data-end=\"21\" data-is-only-node=\"\"\u003eLengths Available\u003c\/strong\u003e: 12 inches or 24 inches \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"259\" data-end=\"438\"\u003e\n\u003cp data-start=\"261\" data-end=\"276\"\u003e\u003cstrong data-start=\"261\" data-end=\"275\"\u003eAdjustable\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"279\" data-end=\"438\"\u003e\n\u003cli data-start=\"279\" data-end=\"357\"\u003e\n\u003cp data-start=\"281\" data-end=\"357\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-start=\"0\" data-end=\"12\" data-is-only-node=\"\"\u003eBendable\u003c\/strong\u003e: The probe can be bent within the first 3–5 inches above the mounting base (marked by a black line) \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"360\" data-end=\"438\"\u003e\n\u003cp data-start=\"362\" data-end=\"438\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-start=\"0\" data-end=\"22\" data-is-only-node=\"\"\u003eCuttable to Length\u003c\/strong\u003e: If shortened, the probe requires additional calibration steps \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"751\" data-end=\"772\"\u003eCalibration Notes\u003c\/h3\u003e\n\u003cul data-start=\"774\" data-end=\"1110\"\u003e\n\u003cli data-start=\"774\" data-end=\"856\"\u003e\n\u003cp data-start=\"776\" data-end=\"856\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eIf the sender is used at full, uncut length: proceed directly to fuel level calibration in the EFIS—no Empty\/Full calibration required. \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"857\" data-end=\"1029\"\u003e\n\u003cp data-start=\"859\" data-end=\"898\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eIf the sender is cut shorter: you must perform a calibration in two stages before EFIS calibration:\u003c\/span\u003e\u003c\/p\u003e\n\u003col data-start=\"901\" data-end=\"1029\"\u003e\n\u003cli data-start=\"901\" data-end=\"943\"\u003e\n\u003cp data-start=\"904\" data-end=\"943\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eSet EMPTY calibration by applying power with the signal line shorted to ground, wait ~10 seconds (for post‑March 2013 models), then measure a stable 0.3 V output.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"946\" data-end=\"1029\"\u003e\n\u003cp data-start=\"949\" data-end=\"1029\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eSet FULL calibration by fully immersing the sender in a tank, repeat with jumper, wait ~20 seconds, confirm ~4.0 V output.\u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1030\" data-end=\"1110\"\u003e\n\u003cp data-start=\"1032\" data-end=\"1110\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eOnce sender-level calibration is complete, proceed with the standard fuel‑level calibration in your EFIS system. \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1117\" data-end=\"1149\"\u003eInstallation \u0026amp; Compatibility\u003c\/h3\u003e\n\u003cul data-start=\"1151\" data-end=\"1462\"\u003e\n\u003cli data-start=\"1151\" data-end=\"1339\"\u003e\n\u003cp data-start=\"1153\" data-end=\"1164\"\u003e\u003cstrong data-start=\"1153\" data-end=\"1163\"\u003eWiring\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cul data-start=\"1167\" data-end=\"1339\"\u003e\n\u003cli data-start=\"1167\" data-end=\"1210\"\u003e\n\u003cp data-start=\"1169\" data-end=\"1210\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eRed wire = +11–28 Vdc supply\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1213\" data-end=\"1256\"\u003e\n\u003cp data-start=\"1215\" data-end=\"1256\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eYellow wire = signal output (0.3 V to 4.0 V)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1259\" data-end=\"1339\"\u003e\n\u003cp data-start=\"1261\" data-end=\"1339\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eBlack wire = ground \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1340\" data-end=\"1420\"\u003e\n\u003cp data-start=\"1342\" data-end=\"1420\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eCompatible with many MGL EFIS and RADAC systems such as the Extreme EMS (signal interpreted in either ohms or voltage mode depending on RADAC switch setting) \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1421\" data-end=\"1462\"\u003e\n\u003cp data-start=\"1423\" data-end=\"1462\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003eNo mechanical floats—ideal for rugged aviation installations and less prone to mechanical failure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-start=\"1469\" data-end=\"1499\"\u003eMechanical \u0026amp; Environmental\u003c\/h3\u003e\n\u003cul data-start=\"1501\" data-end=\"1747\"\u003e\n\u003cli data-start=\"1501\" data-end=\"1583\"\u003e\n\u003cp data-start=\"1503\" data-end=\"1583\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-start=\"0\" data-end=\"14\" data-is-only-node=\"\"\u003eProbe body\u003c\/strong\u003e: concentric tubing (metal inner\/outer with polyester or polymer insulators) \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1584\" data-end=\"1666\"\u003e\n\u003cp data-start=\"1586\" data-end=\"1666\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-start=\"0\" data-end=\"22\" data-is-only-node=\"\"\u003eHousing dimensions\u003c\/strong\u003e: approximately 0.72″ tall and 2.625″ diameter \u003c\/span\u003e\u003cspan class=\"\" data-state=\"closed\"\u003e\u003cspan class=\"ms-1 inline-flex max-w-full items-center relative top-[-0.094rem] animate-[show_150ms_ease-in]\"\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1667\" data-end=\"1747\"\u003e\n\u003cp data-start=\"1669\" data-end=\"1747\"\u003e\u003cspan class=\"relative -mx-px my-[-0.2rem] rounded px-px py-[0.2rem] transition-colors duration-100 ease-in-out\"\u003e\u003cstrong data-start=\"0\" data-end=\"13\" data-is-only-node=\"\"\u003eMaterials\u003c\/strong\u003e: corrosion resistant, epoxy‑sealed electronics for durability across a wide temperature range (approx. −40 °C to +85 °C) \u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Ryzor Tech","offers":[{"title":"12 Inch","offer_id":49358452195425,"sku":null,"price":195.0,"currency_code":"USD","in_stock":true},{"title":"24 inch","offer_id":49358452228193,"sku":null,"price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0605\/7338\/4801\/files\/Screenshot2025-08-04154519.png?v=1792369383","url":"https:\/\/annaskaigrp.com\/products\/mgl-capacitance-fuel-level-senders","provider":"ANNASKAI Group","version":"1.0","type":"link"}